Details
-
2-Position Housing & Mounting Bracket
-
MaxCap® DI™ Cartridge. (The MaxCap® cartridge removes ammonia left by water sources that contain chloramines.)
-
SilicaBuster ™ DI Cartridge
-
Dual-Probe TDS Meter (Determines when the MaxCap® DI™ Cartridge is exhausted. When the output TDS exceeds 75% of the input TDS,change the Cartridge.)
-
Universal Filter Wrench
-
Retail-Ready Package
In many applications, the MAXCAP® DI™ (DI-MC-10) is installed up-stream of a Mixed-Bed or Hi-Silica removal cartridge. For example, if the RO water entering the MAXCAP® DI™ has 20 ppm TDS (Total Dissolved Solids), the original DI cartridge may process about 400 gallons of pure DI water. By placing a MAXCAP® DI™ cartridge in front of the original cartridge, 1200 gallons of water will pass through both cartridges before the MAXCAP® DI™ is exhausted. The original DI cartridge will be only one-third exhausted. A second MAXCAP®DI™ will process another 1200 gallons and the original cartridge will now be two-thirds exhausted. Only after a third MAXCAP® DI™ cartridge processes another 1200 gallons will the original cartridge finally become fully exhausted.
That's 3600 gallons purified with only 4 (3 MAXCAP® DI™ + 1 Mixed-Bed) cartridges, not 9 (9 x 400 = 3600).
Quick Overview
Additional Information
| SKU | MC-DI-2-10HC |
|---|---|
| Manufacturer | SpectraPure |