Free Shipping on Orders $99.00+. Read more.

Hanna Instruments HI729 Checker Fluoride Low Range

Sku: HI729

More Views

Hanna Instruments HI729 Checker Fluoride Low Range

Sku: HI729

$49.00

Availability: Usually Ships In 2 - 3 Business Days After Submission of Order

Be the first to review this product

Hanna Instruments HI729 Checker Fluoride Low Range
You will earn 49 Points for buying this product
OR
Description

Details

Hanna Instruments HI729 Checker Fluoride Low Range

The Hanna Fluoride Low Range Checker® bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits have limited accuracy and resolution since they rely upon the human eye to discern differences in color. Professional instrumentation incorporates a light source such as an LED or tungsten lamp with a filter and a light sensing detector to precisely determine ion concentration. Professional instrumentation offers greater resolution and accuracy but can cost hundreds of dollars. The Hanna Fluoride Low Range Checker® uses a fixed wavelength LED and silicon photo detector to provide the accuracy of professional instrumentation at the affordable price of a chemical test kit.

Details

The HI729 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure fluoride.

Fluoride is one of the very few chemicals that have been shown to cause significant effects in people through drinking water. Fluoride has beneficial effects on teeth at low concentrations in drinking water, but excessive exposure to fluoride in drinking water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects.

Water fluoridation is the controlled addition of fluoride to a public water supply to reduce tooth decay. Fluoridated water operates on tooth surfaces: in the mouth it creates low levels of fluoride in saliva, which reduces the rate at which tooth enamel demineralizes and increases the rate at which it remineralizes in the early stages of cavities. A 1994 World Health Organization expert committee suggested a level of fluoride from 0.5 to 1.0 mg/L, depending on climate. Bottled water typically has unknown fluoride levels, and some domestic water filters remove some or all fluoride.

The HI729 Checker® is simple to use. For this measurement you need 2 vials (#1 and #2); in both vials 2 mL of reagent is added. Deionized water is then added to vial #1 while the sample to be tested is added to vial #2. Both vials are then gently inverted 5 times, and wait 2 minutes. Cuvette #1 is then inserted into the HI729 Checker® and the button pressed to zero; after that, insert cuvette #2 to take a measurement.

Features at-a-glance:

  • Easier to use and more accurate than chemical test kits
  • Dedicated to a single parameter
  • Small size, big convenience
  • Ideal for: Drinking Water, Environmental, Industrial

Specifications

Range 0.00 - 2.00 ppm
Resolution 0.01 ppm
Accuracy @ 25°C/77°F ±0.10 ppm ±5% of reading
Light Source LED @ 575 nm
Light Detector silicon photocell
Method adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery Type (1) 1.5V AAA
Auto-off after ten minutes of non-use
Dimensions 81.5mm x 61mm x 37.5mm (3.2" x 2.4" x 1.5”)
Weight 64 g (2.25 oz.)
Ordering Information HI729 Checker® is supplied with (2) sample cuvettes with caps, fluoride LR reagent starter kit for 5 tests (1 bottle of fluoride LR reagent), syringe with tip, battery, instructions and quick start guide.
Warranty 6 month limited warranty

 

 

Additional Information

Additional Information

Manual No
Product Specs

Manufacturer

Manufacturer Hanna Instruments

Reviews

Be the first to review this product

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Price
Value
Quality