Details

The all new Checker Ammonia LR for fresh water can be used in place of HI 3824 or HI 38049 fresh water test kits.

Range   0.00 to 3.00 ppm NH3-N
Resolution   0.01 ppm
Measurement Method   Colormetric
Accuracy (@25°C/77°F)   ±0.05ppm ± 5% of reading
Light Source   Photodiode @470 nm
Light detector   Silicon photocell

Quick Overview

The HI 733 Checker®HC is a simple, accurate, and cost effective way to measure high ranges of ammonia in fresh water.  Designed as a more accurate alternative to chemical test kits, the HI 733 provides quick, accurate results in four easy steps. 

1.) Step One - Add 1ml of sample and 9ml of reagent “B” to the included cuvette
2.) Step Two - Insert sample into the Checker and zero it out 
3.) Step Three - Remove sample and add reagent “A”
4.) Step Four – Reinsert sample and click the button to measure your results or…
- Press and hold the button for 3 seconds for a time reaction reading

The HI 733 uses an adaptation of the ASTM Manual of water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.


FEATURES/BENEFITS:
* Small palm-sized design
* Accurate from ±1.0ppm ±5% of reading
* Dedicated to a single parameter
* Uses a single AAA battery
* Auto Power Off after 10 minutes in inactivity
* Built-in timer for timed reaction readings

PRIMARY APPLICATIONS:
* Water Quality
* Education
* Wastewater 
* Environmental


Specifications:


Range 0.0 to 99.9 ppm as NH4+
Resolution 0.1 ppm
Accuracy (@20°C/68°F) ±1.0ppm ±5% of reading
Measurement Method Colorimetric
Light Source Photodiode @470 nm
Light Detector Silicon photocell
Method Adaptation of the ASTM Manual of water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.
Power Supply Battery - 1 x 1.5V AAA
Power Auto Off After 10 min. of inactivity
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight 64 g (2.25 oz.)

Additional Information

SKU HI733
Manufacturer Hanna Instruments

Manual

Files

HI733 MSDS Sheets (51.5 KB)